Hussmann m3x-e Scheda Tecnica

Pagina di 8
2 of 8
M3X-E 
Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.
Engineering
Plan Views
Dimensions shown as in. and (mm).
Meat, Delicatessen & Produce
10-2004
NOTE: Case-to-Case Electrical Connections 
are made IN FRONT OF SPLASHGUARD. 
3
/
(120)
Splashguard
31 
5
/
(804)
42
 
(1064)
A
41 
1
/
(1054)
3 In. 
(77 mm)
 
Required 
Air Gap
Refrigeration 
Outlet
Electrical 
Stub Up Area 
6 x 6 
(152x152)
 
Waste Outlet
Waste Outlet
FRONT
26 
1
/
(665)
B
D
8
 
(203)
1
/
(115)
12 
1
/
(307)
41 
1
/
(1054)
43 
7
/
(1114)
C
Wireway
3
/
(120)
26 
1
/
(673)
1
/
(108)
24
 
(612)
33 
1
/
(851)
Electrical 
Field 
Connection
30 
1
/
(768)
M3X
4 ft
6 ft
8 ft
12 ft
General
(A) 
Case Length (without ends or partitions)
48 
3
/
8
(1229)
72 
3
/
8
(1838)
96 
3
/
8
(2448)
144 
1
/
2
(3670)
(Each end and insulated partition adds 1 
1
/
in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front 
(includes bumper)
42 (1064)
42 (1064)
42 (1064)
42  (1064)
Back of case to front of splashguard
33 
1
/
(851)
33 
1
/
(851)
33 
1
/
(851)
33 
1
/
(851)
Back of case to O/S edge of front leg
30 
1
/
(768)
30 
1
/
(768)
30 
1
/
(768)
30 
1
/
(768)
Distance between edges of external legs and center legs
NA
29 
1
/
(750)
41 
1
/
(1054)
41 
1
/
(1054)
Distance between edges of center legs
NA
NA
NA
43 
7
/
(1114)
Distance between front legs and splashguard
3
/
4
(70)
3
/
4
(70)
3
/
4
(70)
3
/
4
(70)
Electrical Service             (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area
36 
1
/
(921)
60 
1
/
(1530)
84 
1
/
(2140)
132 
3
/
(3363)
Back of case to center of stub up area
24 (612)
24 (612)
24 (612)
24 (612)
Length of electrical wireway
26 
1
/
(673)
26 
1
/
(673)
26 
1
/
(673)
26 
1
/
(673)
(C) RH End of case to LH end of wireway
42 
1
/
(1070)
66 
1
/
(1680)
90 
1
/
(2289)
138 
1
/
(3511)
Waste Outlets  (One each end)
(D) RH End of case to the center of LH waste outlet
36 
1
/
(921)
60 
1
/
(1530)
84 
1
/
(2140)
132 
3
/
(3363)
RH End of case to the center of RH waste outlet
12 
1
/
(307)
12 
1
/
(307)
12 
1
/
(307)
12 
1
/
(307)
Back O/S of case to center of waste outlets
31 
5
/
(804)
31 
5
/
(804)
31 
5
/
(804)
31 
5
/
(804)
Schedule 40 PVC drip pipe
1
/
(32)
1
/
(32)
1
/
(32)
1
/
(32)
Refrigeration Outlet
Back of case to center of refrigeration outlet
26 
1
/
(665)
26 
1
/
(665)
26 
1
/
(665)
26 
1
/
(665)
RH end of case to center of refrigeration outlet
8  (203)
8  (203)
8  (203)
8  (203)
PHYSICAL DATA
Merchandiser Drip Pipe (in.)
1
/
4
Merchandiser Liquid Line (in.)
3
/
8
Merchandiser Suction Line (in.)
7
/
8
Wireway