8.0 
REGULATORY AGENCY REQUIREMENTS 
8.1       Safety Certification 
The Monitor does not inhibit customer from certifying product to following safety standards: 
 
• 
UL 1950/CAN/CSA C22.2 No. 950-95 Safety of Information Technology, including electrical 
business equipment 
• 
UL 291Standard for Automated Teller Machine 
• 
EN 60950 Safety of Information Technology, including electrical business equipment. 
8.2       CE Marking (Declaration according to ISO/IEC Guide 22 and EN45014) 
The Monitor does not inhibit customer from conforming to the following EC Directives: 
Council Directive 73/23/EEC and 93/68/EEC (Latest Amendment) on the harmonization of the laws 
of the Member States relating to electrical equipment designed for use within certain voltage limits is 
based on compliance with the following harmonized standards: 
• 
EN 60950 June 2000 
• 
EN 41003:1991 
Council Directive 89/336/EEC, 92/31/EEC and 93/68/EEC (Latest Amendment) on the approximation 
of the laws of the Member States relating to electromagnetic compatibility is based on compliance 
with the following harmonized standards: 
• 
Electromagnetic Emissions  
EN 55022 Class A: 1994 
• 
Electromagnetic Immunity 
EN 50082 part 1:1992 
 
 
 
 
8.3       RFI Emission Certification 
The Monitor is certified to the following emissions standards when installed in customer product 
configuration: 
• 
FCC, Part 15, Paragraph 15.107(b) and 15.109(b), Class A RFI emissions standard. 
• 
EN 55022 Class A: 1994 ? Limits and measurements of radio interference characteristics of 
information technology equipment. 
• 
IEC 1000 3-?2/1995; EN 61000-?3-?2 
Current Harmonic Tests 
• 
IEC 1000 3-?3/1995; EN 61000-?3-?3 
Voltage Fluctuation and Flicker Tests 
 
 
8.4       System Transient Disturbance Requirements 
The Monitor meets the following system transient disturbance requirements: 
8.4.1        Electrostatic Discharge 
The Monitor performs normally when subjected to static electricity discharges from 
persons touching the external surfaces of the Monitor.  Performance is verified by testing 
according to EN 50082-1 (Ref IEC 801-2:1984) at severity level 3 (4 Kv contact discharge, 
8 Kv air discharge).