Planar LC12 Guida Specifiche

Pagina di 27
 
Title:  Engineering Specification: 12.1-inch AMLCD Monitor 
Page 8 of 27 
Document Number: 023-0284-00 
 
          Revision:  A 
• 
Power spectrum is referenced per MIL STD 810 E Environmental Test Method 505.3, Table -II 
Spectral Energy Distribution and permitted tolerances 
• 
Maximum solar power flux = 1120 watts/m
at 65 degrees normal to the Monitor surface.  
• 
These values assume no solar radiation attenuation from the customer-supplied vandal shield.  
3.3       Altitude  
Maximum operating altitude is 3,000 meters [9,850 feet].  Maximum shipping and storage altitude is 
12,000 meters [39,400 feet]. 
3.4       Mechanical Vibration and Shock 
Note: Tests performed with unpackaged Monitors are mounted in a Planar approved rigid retaining 
fixture. 
3.4.1        Vibration 
Non-Operating (sinusoidal): 
10-200 Hz, 0.9g acceleration, 120 seconds per sweep 
for 15 minutes, three axes, (x, y, z). 
 
Following exposure unit shall meet all performance 
requirements. 
Non-operating (random): 
10-200 Hz, 0.02g
2
/Hz, 10 min/axis, three (x, y, z). 
Following exposure unit shall meet all performance 
requirements.  
3.4.2        Shock  
Note: Tests performed with unpackaged Monitors are mounted in a Planar approved rigid 
retaining fixture. 
Non-operating: 
30 g, > 2.5 ms duration, ½ sine, 1 shocks per axis. 
Following exposure unit shall meet all performance 
requirements. 
3.4.3        Shock Packaged Product 
Non-operating: 
30 inch free fall or simulated drop, 1 drop per side, 6 
sides and 1 drop per edge, 3 edges  1 shocks per axis. 
With accelerometer attached to center of product 
display screen, a maximum of 50 G’s is allowed. 
Following exposure unit shall meet all performance 
requirements
.
 
Y (rear)
X (side)
Z (bottom)
DISPLAY