Avery Dennison 9416 xl Guida Specifiche

Pagina di 30
 
The second label shows the model number, software version, communication 
settings, speed, contrast, gap sensor setting, label length, and total number of 
inches printed.   
The third label shows network parameters when the printer is connected to the 
network. When the printer is not connected, zeros print instead of parameters. 
4.  To resume normal printing, turn off the printer, wait two seconds, then turn it back 
on again. 
C a l i b r a t i n g   t h e   S u p p l y  
To calibrate the supply: 
1.  Turn off the printer. 
2.  Press and hold the FEED button while turning on the printer. 
3.  Release the FEED button after the indicator light starts flashing ORANGE.  The 
printer calibrates the black mark or die cut sensor, measures the label length, and 
prints the test labels. 
4.  To resume normal printing, turn off the printer, wait two seconds, then turn it back 
on again. 
Troubleshooting  4-3