Viking Range dert300-4b Guida All'Installazione

Pagina di 9
Interior Cabinet Clearances for proper airflow
Remove the material from this area
for proper air flow into the unit.
3” (7.6 cm)
2” 
(5.1 cm)
2 3/4” 
(7.0 cm)
8” (20.3 cm)
8” (20.3 cm)
3” (7.6 cm)
1 1/2” 
(3.8 cm)
1 1/2” dia.
cutout for
conduit
IIM
MP
PO
OR
RT
TA
AN
NT
T::
The electronic components for the
induction  elements  in  the  rangetop  need  some  air
circulation.  To  ensure  long  life  of  electronic
components,  it  is  required  that  a  minimum  of  8”
(20.3  cm)  of  open  space  remain  between  the
bottom  of  the  unit  and  any  shelf  underneath.  The
maximum  length  of  the  shelf  underneath  is  to  be
18” (45.7 cm)  There should be no partition or shelf
d
diirre
eccttllyy underneath the unit.
8” Min.
(20.3 cm)
18” Max.
(45.7 cm)
6
Proximity to cabinet installation
1.  This rangetop may be installed directly adjacent to existing 36” (91.4 cm) high base cabinets.  
2.  The  rangetop  CANNOT be  installed  directly  adjacent  to  sidewalls,  tall  cabinets,  tall
appliances,  or  other  side  vertical  surfaces  above  36”  (91.4  cm)  high.    There  must  be  a
minimum  of  6”  (15.2  cm)  side  clearance  from  the  rangetop  to  such  combustible  surfaces
above the 36” (91.4 cm) counter height.
3.  Within the 6” (15.2 cm) side clearance to combustible vertical surfaces above 36” (91.4 cm),
the maximum wall cabinet depth must be 13” (33.0 cm) and wall cabinets within this 6” (15.2
cm) side clearance must be 18” (45.7 cm) above the 36” (91.4 cm) high countertop. 
4.  Wall cabinets above the rangetop must be a minimum of 36” (91.4 cm) above the rangetop
cooking surface for the full width of the rangetop.
13” Max
(33.0 cm)
36” Min.
(91.4 cm)
7 1/2”
(19.1 cm)
18” Min.
(45.7 cm)
6” Min.
(15.2 cm)
36” Min.
(91.4 cm)
S
SIID
DE
E
F
FR
RO
ON
NT
T
5
Installation
Clearances
Detailed View of Bottom Support