Clavia electro 3 Guida Utente

Pagina di 27
Ctrl Pedal Mode
A connected control pedal can be used to control several things . It 
can be used as a solitary organ swell pedal (swell is a combination of 
volume and frequency control), as a combined organ swell/volume 
pedal for the samples type, and finally as a swell/volume pedal for all 
the instrument sections (incl . the pianos) in the Nord Electro 3 . 
Range: O – Organ swell (default), S – Organ swell/sample volume, 
P - Organ swell/sample volume, piano volume
A connected control pedal will always be active if the P-Wa or the 
 
M
RM effect is activated, regardless of the Ctrl Pedal Mode setting.
Organ Trig Mode
This allows you to change how the Nord C2 keyboard triggers the 
organ sounds . When “Fast/High” is selected, you will trigger the organ 
sounds before the key reaches the end of its travel . This mode closely 
mimics the way a vintage tonewheel organ or a pipe organ trigger its 
notes . 
Range: F - Fast (default), n - normal
            High trigger point 
 
Low trigger point
Drawbar Speed
This sets the speed with which the drawbars will increase or decrease 
the values when the drawbar buttons are held down .
Range: F- Fast (default), S- slow
MIDI Menu
MIDI Channel
This sets the MIDI Channel that the Nord Electro 3 transmits and 
responds to .
Range: 1-16, OF - off (default = 1)
Lower Channel
This sets the MIDI channel that the Lower Manual of the Nord Electro 3 
organ section responds to when the organ split and the MIDI split 
modes are active .
Range: 1-16, OF - off (default = 2)
Local Control
This allows you to set if the Nord Electro 3 keyboard and front panel 
controls should control internal Programs or only send note and 
controller messages via MIDI . Local On is the normal “mode” . In Local 
Off mode, the front panel and keyboard action are transmitted via MIDI 
only and does not control the internal sound(s) directly .
Range: On (default), Off
Local defaults back to mode On every time the Nord Electro 3 is 
 
M
powered on.
Control Change (CC) Mode
This setting specifies how the front panel’s knobs and buttons are han-
dled in the MIDI communication with MIDI Control Change messages . 
You can select if the panel controls and functions should either send or 
receive, or both or if Control Change messages should be ignored .
Range: Sr (send & receive - default), r (receive only), S (send only), 
Off
Program Change Mode
Specifies how the Nord Electro 3 should handle MIDI Program Change 
messages .
Range: Sr (send & receive - default), r (receive only), S (send only), 
Off
MIDI Split Mode
If MIDI Split mode is On and the Organ is set to a split operation, the 
lower manual will be exclusively controlled via incoming MIDI infor-
mation to the Electro 3’s MIDI input . If you connect an external MIDI 
keyboard, the Electro 3 can then be used in a dual manual fashion . 
Range: On, Off (default) 
Send CC 
You can perform a dump of all the active Program’s parameters as 
MIDI Control Change messages . Press the Store button to perform the 
dump .
Dump One
This allows you to perform a MIDI SysEx dump of the currently selected 
Program . Press the Store button to perform the dump .
Dump All
This allows you to perform a MIDI SysEx dump of all the Programs in 
the Electro 3 . Press the Store button to perform the dump .
In the MIDI chapter, on page 23 is a description on how the Electro 3 
receives a Sys Ex dump . 
18 | NordElEctro3UsErMaNUalosv3.x