Symbol Barcodes - Scanner Parameters – SE Barcode Type Specific
89
E-SW-SCANNERPG-L
Integrated Scanner Programming Guide
Standard Code 128 barcodes which do not have a leading FNC1 may still be used, but are not
encoded according to the EAN-128 convention. Standard Code 128 and UCC/EAN-128 may be
mixed in an application. The scanner autodiscriminates between these symbols, and can enable or
disable one or both code types via barcode menus. The following table indicates the behavior of the
scanner in each of the four possible parameter settings.
encoded according to the EAN-128 convention. Standard Code 128 and UCC/EAN-128 may be
mixed in an application. The scanner autodiscriminates between these symbols, and can enable or
disable one or both code types via barcode menus. The following table indicates the behavior of the
scanner in each of the four possible parameter settings.
Standard
Code 128
Code 128
UCC/
EAN-
128
EAN-
128
Effect and Example
Disable
Disable
No Code 128 symbols can be read.
Disable
Enable
Read only symbols with leading FNC1.
Examples:
FNC1
ABCD
FNC1
E are read as ABCD
29
E
A
FNC1
BCD
FNC1
E are read as ABCD
29
E
FNC1FNC1
ABCD
FNC1
E are read as ABCD
29
E
ABCD
FNC1
E cannot be read
ABCDE cannot be read
Enable
Disable
Read only symbols without leading FNC1.
Examples:
FNC1
ABCD
FNC1
E cannot be read
A
FNC1
BCD
FNC1
E cannot be read
FNC1FNC1
ABCD
FNC1
E cannot be read
ABCD
FNC1
E is read as ABCD
29
E
ABCDE is read as ABCDE
Enable
Enable
Read both types of symbols.
Examples:
FNC1
ABCD
FNC1
E are read as ABCD
29
E
A
FNC1
BCD
FNC1
E are read as ABCD
29
E
FNC1FNC1
ABCD
FNC1
E are read as ABCD
29
E
ABCD
FNC1
E is read as ABCD
29
E
ABCDE is read as ABCDE