Ricoh is100 Guida All'Installazione Rapida

Pagina di 167
 
         Troubleshooting   7-13 
Replacing the Snap-in Pad Module 
 
After scanning approximately 20,000 pages through the ADF, the pad may 
be worn out and you may experience problems with document feeding.  In 
this case, it is highly recommended to replace the pad module with a new 
one.  For ordering the pad module, please consult your nearest dealer and 
follow the procedure below to replace it.   
 
Disassembling Procedure 
 
1.  Gently open the ADF front cover to the left.   
2.  Press both arms of the ADF snap-in pad module inwardly with your fingers 
to pull out the ADF snap-in pad module.   
 
 
 
 
 
 
Do not touch the metal fingers of the ADF pad module. The edges are sharp and 
touching them may result in injury.