Electrovoice cp3000s Guida Utente

Pagina di 36
MAINS OPERATION & RESULTING POWER AMP TEMPERATURES
The following tables are useful in determining power supply and cabling requirements.
The power drawn from the mains network is converted into acoustic output to feed the connected 
loudspeaker systems plus heat. The difference between drawn power and dispensed power is referred 
to as leakage power or dissipation (
P
d
). The amount of heat resulting from power dissipation might 
remain inside of a rack-shelf and needs to be diverted using appropriate measures. The following table 
is meant as auxiliary means for calculating temperatures inside of rack-shelf systems/cabinets and the 
ventilation efforts necessary.
The column “Pd” lists the leakage power in relation to different operational states. The column “BTU/
hr” shows the dispensed heat amount per hour.
MAINS OPERATION & RESULTING 
(1) Sine Modulation (1kHz)                (2) VDE-Noise                         (3) 1BTU = 1055.06J = 1055.06Ws     
(4) 10% Mains Over Voltage              (5) Pd = Leakage Power         
           
The following factors allow direct proportional calculation of the mains current Imain for different mains 
supply voltages: 
100V = 2.3;  120V = 1.9;  220V = 1.05; 240V = 0.96
CP4000S
U
mains
 [V]
I
mains
 [A]
P
mains
 
[W]
P
out
 [W]
Pd 
(5)
[W]
BTU/hr
(3)
idle
230
1.3
145
-
145
495
Max. Output Power @ 8Ω
(1)
230
15.7
2500
2 x 900
700
2388
Max. Output Power @ 4Ω
(1)
230
26.0
4400
2 x 1500
1400
4777
 1/3 Max. Output Power @ 4Ω
(1)
230
14.7
2320
2 x 500
1320
4504
 1/8 Max. Output Power @ 4Ω
(1)
230
6.9
990
2 x 188
615
2098
 1/8 Max. Output Power @ 4Ω
(2)
230
7.3
1070
2 x 188
695
2371
 1/8 Max. Output Power @ 4Ω
(2),(4)
253
7.7
1200
2 x 227
746
2546
Normal Mode (-10dB) @ 4Ω
(1)
230
6.3
895
2 x 150
595
2030
Rated Output Power (0dB) @ 4Ω
(1)
230
23.5
3900
2 x 1200
1500
5118
Alert (Alarm) Mode (-3dB) @ 4Ω
(1)
230
16.4
2630
2 x 600
1430
4879
Max. Output Power @ 2Ω
(1)
230
40.7
7200
2 x 2100
3000
10236
 1/8 Max. Output Power @ 2Ω
(1)
230
10.3
1525
2 x 263
1000
3412
 1/8 Max. Output Power @ 2Ω
(2)
230
10.4
1535
2 x 263
1010
3446
9
CP3000S
U
mains
 [V]
I
mains
 [A]
P
mains
 
[W]
P
out
 [W]
Pd 
(5)
[W]
BTU/hr
(3)
idle
230
0.8
80
-
80
273
Max. Output Power @ 8Ω
(1)
230
11.0
1780
2 x 600
580
1980
Max. Output Power @ 4Ω
(1)
230
19.5
3240
2 x 1100
1040
3549
 1/3 Max. Output Power @ 4Ω
(1)
230
11.3
1740
2 x 366
1008
3439
 1/8 Max. Output Power @ 4Ω
(1)
230
4.6
640
2 x 137
366
1249
 1/8 Max. Output Power @ 4Ω
(2)
230
6.0
850
2 x 137
576
1965
 1/8 Max. Output Power @ 4Ω
(2),(4)
253
6.1
950
2 x 166
618
2109
Normal Mode (-10dB) @ 4Ω
(1)
230
4.2
580
2 x 110
360
1230
Rated Output Power (0dB) @ 4Ω
(1)
230
17.6
2860
2 x 900
1060
3617
Alert (Alarm) Mode (-3dB) @ 4Ω
(1)
230
12.6
1980
2 x 450
1080
3685
Max. Output Power @ 2Ω
(1)
230
30.3
5280
2 x 1600
2080
7100
 1/8 Max. Output Power @ 2Ω
(1)
230
7.0
1030
2 x 200
630
2150
 1/8 Max. Output Power @ 2Ω
(2)
230
8.4
1250
2 x 200
850
2900