8. Chink the wall and window with soft
    sponges or rubber bits in order to
    refrain from outside noises coming
    in or cooling air going out.
9. Air conditioner being fixed,insert the
    power plug in the socket, open the
    operation panel cover, turn the temperaure
    setting to "Test run", turn successively the
    mode selection to "Hi fan" and "Hi cool",
    "Lo cool" and "Lo fan", inspect the air
    conditioner's start and running performance.
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service
    agent or a similar qualified person. Power cable:3x1.5mm
2
3. After installation, the power plug should be easily reached.
4. The wiring method should be in line with the local wiring standard.
Cooling
Indoor side
Outdoor side
Maximum:
Minimum:
Maximum:
Minimum:
D.B
/W.B
D.B
/W.B
D.B
32°C
/23°C
18°C
/14°C
43°C
/26°C
18°C
1. Applicable ambient temperature range:
The machine is adaptive in following situation
Wall
Drain hose
Fig. 5
Installation instruction
D.B
/W.B