Managing Remote Access Concentrators Using Annex Manager
Appendix A    RAC Parameters
A-8
bidirectional_modem
allows you to transmit and receive data after connecting to an asynchronous port.
When you choose
disabled
, you can connect to the port, but communication
cannot occur until the Data Carrier Detect (DCD) modem signal is active. This
parameter is obsolete in Release 10.1.A and in subsequent releases.
broadcast_addr
specifies the IP address for RAC broadcasts (network.255 or network.0).
broadcast_direction
controls the direction in which a RAC sends an administrative broadcast
message. When you choose
network
, the RAC sends a message from the network
side of the connection. If you choose
port
, it sends a message from the port side.
You can use this parameter only when the
mode
 parameter is set to
slave
.
bypass
removes the T1 engine from the network. You should enter
enabled
 when you
first install a RAC or when the T1 engine is not functioning properly.
Type
Async
Values
enabled or disabled
Default
disabled
Lists
Async Port, Flow Control, Modem
Type
RAC
Values
IP Address
Default
0.0.0.0
Lists
RAC Only, Basic RAC
Type
Async
Values
port or network
Default
port
Lists
Async Port, Basic Async Port, Modem
Type
T1 DS1
Values
enabled or disabled
Default
disabled
Lists
DS1 Line, T1_DS1