Nortel 4000 Guida Utente

Pagina di 351
A-101
Appendix A    RAC Parameters
Managing Remote Access Concentrators Using Annex Manager
tmux_enable
controls whether a RAC uses TMux to multiplex small TCP or UDP packets into
a single IP packet. The host must support TMux. If you choose
enabled
 and the
host does not support TMux, the RAC does not support multiplexing.
tmux_max_host
specifies the maximum number of host addresses allowed in the TMux address
table. If the number of host addresses exceeds the number you enter here, the
RAC discards the oldest entry.
tmux_max_mpx
specifies the largest user packet that can be placed in a TMux packet. The RAC
does not multiplex larger packets, but passes them directly to the IP layer.
tni_circuit_id
contains the transmission vendor’s circuit identifier used for customer service
calls.
Type
RAC
Values
enabled or disabled
Default
disabled
Lists
RAC Only, TMux
Type
RAC
Values
10 through 255
Default
64
Lists
RAC Only, TMux
Type
RAC
Values
5 through 65535
Default
700
Lists
RAC Only, TMux
Type
T1 DS1
Values
0 to 128 characters
Default
“ “
Lists
DS1 Line, T1_DS1