Extreme 3802 Guida All'Installazione

Pagina di 394
 
140
Extreme Networks Consolidated "i" and "e" Series Hardware Installation Guide
Alpine 3800 Series Switch Models
Console (RS-232) port for accessing the CLI
Dedicated 10BASE-T/100BASE-TX port for out-of-band management using CLI, ExtremeWare Vista, 
or SNMP
Port Connections
The Alpine 3800 series switches support different port configurations on the different Alpine I/O 
modules, as described in Table 24.
CAUTION
Modules that use SX, LX, and LX70 interfaces contain Class 1 laser devices. Invisible laser radiation 
can occur when open. Avoid direct eye exposure to the beam.
1 The GM-4Xi supports 1000BASE-SX, 1000BASE-LX, and 1000BASE-LX70.
3 The GM-16X
3
 supports 1000BASE-X.
4 The GM-16T
3
 supports 10/100/1000BASE-T autonegotiation.
5 The FM-8Vi has eight internal loopback ports for rate shaping. Module supports 10BASE-S.
Power Supplies
The Alpine 3800 series switch supports the following types of power supplies:
AC —Auto-sense for 110 and 220 VAC power
DC—Requires -48 VDC nominal input line voltage
If two power supplies are installed in the switch, both installed power supplies must be of the same 
type. 
Table 24: Port configurations available on Alpine I/O modules
Ethernet Ports
Module
 10BASE-T/
100BASE-TX
100BASE-TX/
1000BASE-T
 GBIC
1000BASE-SX
 100BASE-FX  OTHER
GM-4Ti
4
GM-4Xi
4
1
GM-4Si
4
GM-16X
3
16 Mini-GBIC
3
GM-16T
3
16
4
FM-32Ti
32
FM-24Ti
24
FM-24SFi
24
FM-24MFi
24
FM-8Vi
8 VDSL
5
WM-4T1i
2
4 T1 
WM-4E1i
2
4 E1 
WM-1T3i
2
1 T3