MAINTENANCE
Permanant Drain Installation (optional):
The condesate water can be removed directly from the unit to a drain
through a garden hose with the included adapter.  
1. Turn the power off before beginning work.
2.  Use a screwdriver to remove the knock-out at the back of the unit.
(Fig.7)
3.  Slide the garden hose adapter (supplied) over the condensate 
drain through the knock-out hole. (Fig 8)
4. The garden hose should lead to a floor drain or other appropriate
drain source. The garden hose should have no inclines or sharp 
bends. (Fig 8)
Permanant drain
knock-out
Garden Hose
Hose Adapter
Side View
To floor drain
Condensate Drain
Filter
Filter Cleaning
1. Turn the power off. 
2. Use a vacuum cleaner attachment or brush to clean the front grille. 
3. Remove the filter.
4. To clean the filter, wash in warm, soapy water, rinse and shake dry. 
Cleaning is recommended monthly, or as conditions require. 
Proper use and care of your dehumidifier will help ensure longer life of
the unit. It is recommended to annually inspect and clean the coils and
condensate water passages. Expense of annual inspection is the 
consumers’ responsibility.
Note: A piece of tape is
attached to the container
to ensure safe shipping.
This piece of tape may be
removed.
7
8
Condensate
Container
Handle
Condensate 
Drain
5
6
To empty the Container:
When the condensate water container is full, the indicator lights up.
1.  Turn the power off before removing container. Wait 3 minutes for
any remaining water to drain into the condensate container.
2.  Tilt the container forward then lift carefully by the handle.
3.  Empty and gently re-insert the container.  