Fedders b6q10f2a Guida Al Funzionamento

Pagina di 24
5
Power Control
The Power Control turns the unit on and off.
Set Temperature/Timer Display
Shows the set temperature when the unit is in operation and hours
when the timer is being set. THE TEMPERATURE DISPLAY ONLY
SHOWS THE SET TEMPERATURE, NOT THE ACTUAL ROOM TEMPER-
ATURE.
Temperature/Timer Hour Controls
These buttons are used to raise or lower the set temperature in incre-
ments of 1° from 66°F to 88°F. By depressing both buttons at once, the
display will toggle between Celsius and Fahrenheit. When the timer is
being set, these buttons are used to change the hour setting in incre-
ments of 1 from 00 to 24.
Check Filter Light/Reset 
(some models)
After 250 hours of usage the Check Filter light 
will turn on. At this time, the filter needs to be removed and cleaned
(see page 8). After the filter is cleaned and repositioned, depress the
Reset 
button. This will restart the counter and turn the light off.
Mode Control
A green light will indicate which mode is currently 
being utilized.
Cool Mode –
The unit will circulate and cool the air.
Heat Mode (Heat Models Only)–
The unit will circulate and heat
the air.
Heater Safety Feature- When heater is powered off, low fan will auto-
matically stay on and run for 60 seconds to ensure the removal of resid-
ual heat, meanwhile, the Low Fan LED blinks until the low fan stops.
Fan Mode –
The unit will only circulate the air.
Energy Saver Mode –
(The energy saver mode is designed to operate with Cool mode only)
The fan will switch from the set fan speed to LO whenever the compres-
sor turns off in response to the thermostat. When the compressor cycles
back on, the unit will return to the original fan setting. 
Fan Speed Control
High, Medium*, Low and Auto
The settings are adjusted with the Fan Speed Control, each time the but-
ton is depressed it changes the setting. A green light will indicate which
setting is currently being used.
When the AUTO feature is selected while the air conditioner is in the
COOL or HEAT mode, the fan speeds will change automatically as the
temperature in the room changes.
COOL Mode
• 7° or more above the set temperature 
will use HI FAN.
• 4° or less above the set temperature 
will use LO FAN.
HEAT Mode (Heat models only)
• 9° or more below the set temperature 
will use HI FAN.
• 4° or less below the set temperature 
will use LO FAN.
*MEDIUM FAN NOT available on HEAT models.
Set Temperature/Timer
Display
Temperature/Timer
Hour Controls
Timer Control
Fan Speed Control
Mode 
Control
Power
Control
A
A.
D.
B.
E.
C.
F.
B
C
D
E
F
Built-in three minute timing delay.
This electronic controlled unit will not automatically
resume operation after a power failure.
If this electronic unit will not respond to touch pad or
remote control commands, it is necessary to unplug the
unit from the electrical outlet for five seconds and then
plug the unit back in.
Caution: 
Do not block air circulation to outside louvers 
of cabinet.
Do not block air flow inside with blinds, curtains, or
furniture, or outside with shrubs, enclosures, or other
buildings.
Do not run air conditioner with outside protective
cover in place. This could result in mechanical dam-
age within the air conditioner.
The heat from this unit is designed
only as a supplemental heat 
source in addition to 
regular heating systems. 
OPERATION