ELECTRICAL REQUIREMENTS & SAFETY PRECAUTIONS
IMPORTANT SAFETY INSTRUCTIONS
Warning
Electrical Shock Hazard
• Plug unit only into grounded electrical outlet.
• Do not use an extension cord or plug adapter with this unit.
• Do not operate unit with decorative front or filter removed. 
• Failure to follow these precautions could result in electrical shock, fire or
personal injury.
• The air conditioner has a serial plate rating of 230 volts. It must have its own
fuse or circuit breaker, and no other device or unit should be operated on
that fuse or circuit breaker.
• We recommend that a qualified electrician install unit in accordance with the
National Electrical Code and local codes and ordinances.
• Do not operate this air conditioner without proper time delay circuit
protection (circuit breaker or fuse). Refer to serial plate for proper power
supply requirements.
• Use copper conductors of correct wire gauge and protector size only.
• Do not alter cord or plug end. Do not remove warning label on cord.
Important Grounding Requirements
•Air conditioner has a three-prong grounding plug on the power supply cord,
which must be plugged into a properly grounded three-prong wall receptacle
for your protection against possible shock hazard.
Use a single outlet grounding type wall receptacle to match the cord plug.
(Fig. 2)
Three-prong grounding
plug. 
Do not alter plug end.
Single outlet grounding wall
receptacle
Additional Safety Precautions 
•  Do not cut, alter or remove any of the expanded polystyrene (styrofoam)
inside this air conditioner.
•  Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance. The fumes can create a fire hazard or
explosion.
•  Do not introduce objects in the air discharge area. This could cause
permanent damage to your unit.
• Do not pour liquids on the air conditioner as this could cause a malfunction.
With the unit unplugged, use a damp cloth for cleaning your unit.
• Avoid using strong solvents to clean the air conditioner. 
• Clean the air conditioner filter every two weeks to avoid overheating caused
by air obstruction. Do not operate without filter.
• Do not obstruct the air intake area of your air conditioner, as this could cause
overheating, thus activating the units security switch and shutting off the unit.
• Do not block air circulation to outside louvers of cabinet.
• Do not block air flow inside with blinds, curtains, or furniture, or outside with
shrubs, enclosures, or other buildings.
• Do not run the air conditioner with an outside protective cover in place. This
could result in fire or mechanical damage within the air conditioner
.
A
A
B
B
RECOMMENDED CIRCUIT 
WIRE SIZES 
(As installed per building code) :
PROTECTOR SIZE
WIRE GAUGE
30 AMP
#10 MINIMUM
250V
30A
1
2