ELECTRICAL REQUIREMENTS 
& SAFETY PRECAUTIONS
IMPORTANT
Warning
Electrical Shock Hazard
• Plug unit only into grounded electrical outlet.
• Do not use an extension cord or plug adapter with this unit.
• Do not operate unit with decorative front or filter removed. 
• Failure to follow these precautions could result in electrical shock, fire or
personal injury.
• If the air conditioner has a serial plate rating of 115 volts and greater than 7.5
amps, it must have its own fuse or circuit breaker, and no other device or unit
should be operated on that fuse or circuit breaker. If the air conditioner has a
serial plate rating of 230 volts, it must have its own fuse or circuit breaker, and
no other device or unit should be operated on that fuse or circuit breaker.
• We recommend that a qualified electrician install unit in accordance with the
National Electrical Code and local codes and ordinances.
• Do not operate this air conditioner without proper time delay circuit
protection. Refer to serial plate for proper power supply requirements.
• Use copper conductors of correct wire gauge and protector size only.
• Do not alter cord or plug end. Do not remove warning label on cord.
Important Grounding Requirements
•Air conditioner has a three-prong grounding plug on the power supply cord,
which must be plugged into a properly grounded three-prong wall receptacle
for your protection against possible shock hazard. For models up to and
including 7.5 amperes, use a grounding type wall receptacle to match the
cord plug. 
•For models above 7.5 amperes use a single outlet grounding type wall
receptacle to match the cord plug.
Three-prong grounding plug. 
Do not alter plug end.
Single outlet grounding wall receptacle
Grounded three-prong wall receptacle
Additional Safety Precautions
• Do not cut, alter or remove any of the expanded polystyrene (white foam)
inside this air conditioner.
• Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance. The fumes can create a fire hazard or
explosion.
• Do not introduce objects in the air discharge area. This could cause
permanent damage to your unit.
• Do not pour liquids on the air conditioner as this could cause a malfunction.
With the unit unplugged, use a damp cloth for cleaning  your unit.
• Avoid using strong solvents to clean the air conditioner. 
• Clean the air conditioner filter every two weeks to avoid overheating caused
by air obstruction. Do not operate without filter.
• Do not obstruct the air intake area of your air conditioner, as this could
cause overheating, thus activating the unit’s security switch and shutting off
the unit.
• Do not block air circulation to outside louvers of cabinet.
• Do not block air flow inside with blinds, curtains, or furniture, or outside
with shrubs, enclosures, or other  buildings.
• Do not run the air conditioner with an outside protective cover in place.
This could result in fire or mechanical damage within the air conditioner
.
A
A
B
B
C
C
RECOMMENDED CIRCUIT 
WIRE SIZES  
(As installed per building code) :
PROTECTOR SIZE
WIRE GAUGE
15 AMP
#14 MINIMUM
20 AMP
#12 MINIMUM
30 AMP
#10 MINIMUM
125V
15A
250V  
20A
250V
30A
250V  
15A