Fedders c1018bbd Guida Utente

Pagina di 8
15 ft
20 ft.
25 ft
C1018B
A24B1
E3009A16
5
/
16
5
/
8
5
/
16
5
/
8
3
/
8
3
/
4
C1024B
A24B1
E3009A16
5
/
16
5
/
8
5
/
16
5
/
8
3
/
8
3
/
4
C1030B
A36B1
E3618A16
5
/
16
3
/
4
5
/
16
3
/
4
3
/
8
3
/
4
C1036B
A36B1
E3618A16
3
/
8
3
/
4
3
/
8
3
/
4
3
/
8
7
/
8
C1042B
A42B2
E4824A20
3
/
8
3
/
4
3
/
8
3
/
4
3
/
8
7
/
8
C1048B
A48B2
E6026A20
3
/
8
7
/
8
3
/
8
7
/
8
3
/
8
1
1
/
8
C1060C
A60B1
E6037A21
3
/
8
7
/
8
3
/
8
7
/
8
3
/
8
1
1
/
8
C1218B
A24B1
E3009A16
5
/
16
5
/
8
5
/
16
5
/
8
3
/
8
3
/
4
*C1224B
*A30B1
E3618A16
5
/
16
5
/
8
5
/
16
5
/
8
3
/
8
3
/
4
C1230B
A36B1
E3618A16
3
/
8
3
/
4
3
/
8
3
/
4
3
/
8
7
/
8
C1236B
A36B2
E4824A16
3
/
8
3
/
4
3
/
8
3
/
4
3
/
8
7
/
8
C1242C
A48B2
E6026A20
3
/
8
7
/
8
3
/
8
7
/
8
3
/
8
7
/
8
C1248C
A48B2
E6026A20
3
/
8
7
/
8
3
/
8
7
/
8
3
/
8
7
/
8
C1260C
A60B1
E6037A21
3
/
8
7
/
8
3
/
8
7
/
8
3
/
8
1
1
/
8
MINIMUM RECOMMENDED TUBE O.D.
LIQUID LINE SUCTION LINE (in.)
*  For C1224B only, use LOW speed setting on Air Handler.
** Requires time delay relay to obtain SEER rating.
UNITS ARE FACTORY CHARGED FOR 25’ OF LINE SET TUBING.
ADJUST CHARGE 0.41 oz PER FOOT OF VARIATION FROM CHART FOR 
5
/
16
" AND 
5
/
8
" LINE SET.
ADJUST CHARGE 0.65 oz PER FOOT OF VARIATION FROM CHART FOR 
3
/
8
" AND 
3
/
4
" LINE SET.
ADJUST CHARGE 0.67 oz PER FOOT OF VARIATION FROM CHART FOR 
3
/
8
" AND 
7
/
8
" LINE SET.
ADJUST CHARGE 0.72 oz PER FOOT OF VARIATION FROM CHART FOR 
3
/
8
" AND 1
1
/
8
" LINE SET.
CONDENSER
MODEL NUMBER
AIR HANDLER
MODEL
NUMBER
COIL**
MODEL
NUMBER
(Included with 
Air Handler)
Depending on match-ups, the indoor piston may need to be changed. The indoor expansion
device size and type are located on the outdoor unit’s series and rating plate.
NOTE:
THE C1260C, AND C1048B MODELS REQUIRE A TXV KIT WHICH MUST BE
PURCHASED AS AN ACCESSORY KIT AND IS REQUIRED TO COMPLETE THE
SYSTEM INSTALLATION.
The piston is located in the distributor fitting on the liquid line.
To change the piston, remove stub tube nut (left-hand thread) and separate the liquid line
from the distributor, then the piston. Install the correct piston with the rounded end toward
the distributor. Reinstall the O-ring and stub nut (do not nick or handle the O-ring). 
NOTE:
ON PRECHARGED COIL, THE REFRIGERANT WILL HAVE TO BE REMOVED
PRIOR TO CHANGING THE PISTON.
The information in this manual supersedes and replaces the previous instruction/operation manual with regard to split system air conditioning
products. Illustrations cover the general appearance of the units at the time of publication and the manufacturer reserves the right to make
changes in design and construction at any time without notice.
For replacement parts contact:
CareCo
415 Wabash Ave.
Effingham, IL 62401
Phone: 1-866-829-2440
AIR HANDLER & EVAPORATOR MATCH-UPS
TO INSTALL PISTON