Removing and Installing Components
Removing and Installing RAIDStation7 Ultra160 SCSI Stor-
age Array in a Rackmount Cabinet
The rackmount Storage Array can be installed in a standard 19-inch rack cabinet. 
To ensure correct functionality of the rackmounted Storage Array, the guidelines 
set out previously regarding environmental recommendations must be followed.
NOTE: When installing or removing a rackmount Storage Array, you must 
work with at least one other person. This is necessary to prevent personal 
injury and damage to the shelf.
Removing a Storage Array From a Rack Cabinet
1.
Shut down the host system and turn off the power.
2.
Turn off the power switch on the rear of the Storage Array and disconnect its 
power cords.
3.
Disconnect all the cables from the rear of the Storage Array.
4.
Remove the screws from the flanges of the Storage Array mounting bracket.
5.
Remove the Storage Array from the equipment rack cabinet.
Installing a Storage Array in a Rack Cabinet
1.
On each of the front mounting rails of your equipment rack cabinet, select 
four holes that are spaced appropriately for the mounting holes on the Stor-
age Array.
2.
Align the holes on the flanges of the Storage Array with the holes you have 
chosen in (1) above.
3.
Insert two of the screws provided with the Storage Array into the holes on 
the bottom flange of the Array and mounting holes of the equipment rack.
4.
Insert the screws in the top flanges.
5.
Tighten the screws.
6.
Ground per Figure 2-1.