Removing and Installing Components
Advanced Cooling Module (ACM) Removal and Installation
The RAIDstation7 Storage Array is supplied with three ACMs mounted on the 
rear. The ACMs are removable and hot swappable. The air flow created by the 
ACM is from front to rear. 
WARNING: Once you have removed an ACM from an operating Storage 
Array, you must block the resulting hole within 3 minutes. The hole should 
be blocked by installing a new ACM or by leaving the failed ACM in position 
until a replacement is obtained. Failure to do so can seriously restrict air 
flow and cooling within the Storage Array.
Removing an Advanced Cooling Module (ACM)
1.
Loosen the two captive panel fasteners that secure the ACM to the disk 
shelf.
2.
Using the ACM handle, pull the ACM assembly out of the disk shelf.
Installing an Advanced Cooling Module (ACM)
1.
Hold the ACM assembly at 90 degrees to the disk shelf.
2.
Insert the ACM into the empty ACM slot.
3.
Align the two panel fasteners on the ACM with the threaded holes on the 
disk shelf.
4.
Tighten the panel fasteners.