AXIS 210/211 - The I/O Terminal Connector
The I/O Terminal Connector
Pinout and Interface
The 4-pin I/O terminal connector provides the interface to: 
• 1 transistor output
• 1 digital input
• auxiliary power and GND
The terminal connector is used in applications for e.g. motion detection, event triggering, 
time lapse recording, alarm notification via e-mail, image storage to FTP locations, etc.
• Input - for connecting e.g. a push button. If the push button is pressed, the state 
changes and the input becomes active (shown under Event Configuration > Port 
Status).
• Output - connects e.g. an alarm device that can be activated by Output buttons 
on the Live View page, or by an Event Type. The output will show as active 
(Event Configuration > Port Status) if the alarm device is activated. 
Connect input/output devices to the terminal connector as follows:
1. Loosen the corresponding screw on top of the pin (see above for the correct pin to 
Pin
Function 
Description
4
Transistor Output
With a maximum load of 100mA and a maximum voltage of 24V DC, this output 
has an open-collector NPN transistor with the emitter connected to pin 1 (GND). 
If used with an external relay, a diode must be connected in parallel with the load, 
for protection against voltage transients.
3
Digital Input
Connect to GND to activate, or leave floating (or unconnected) to deactivate.
2
Auxiliary DC Power Input
7-20 VDC/max 5W. Electrically connected in parallel with the PS-K power 
connector, this pin provides an auxiliary connector for mains power to the unit. If 
the unit is powered via this pin, a fuse should be used (rating: 1A Slow).
 
This pin can also be used to power auxiliary equipment, max 100mA, but note that 
this is not possible when the AXIS 211 is powered by PoE.
1
GND
Pin 4
Pin 3
Pin 2
Pin 1
Pin 4