Normal Operation
Two fan trays with a total of four functioning fans must be installed and operating 
at all times. If one fan in a fan tray fails, replace the entire fan tray as soon as 
possible. 
CAUTION: All four fans must be operational when the Switch 4005 is powered on 
to ensure proper cooling of the chassis. 
CAUTION: The Switch 4005 chassis will continue to run if one fan fails. However, 
replace the fan tray as soon as possible.
See the Ventilation Requirements and Environmental Specifications in Chapter 3
All Switch 4005 chassis have two fan trays preinstalled at the manufacturing 
center. You do not need to install a fan tray until one of the original fan trays fails 
or is operating intermittently. 
Maintenance
Ensure that the ambient environment for the Switch remains within the 
specifications in Chapter 3. In addition, ensure that the immediate area around the 
Switch 4005 is free from dust or small debris and that the module and fan vents 
are unobstructed. There are no user-serviceable parts on a fan tray. 
If Failure Occurs
If one or both of the fans in a fan tray fails or operates intermittently, remove and 
reinsert the fan tray as described in sections “Removing a Fan Tray” and “Installing 
a Fan Tray” i
n this chapter. If problems continue, remove the fan tray and replace it 
with a new one. There are no user-serviceable parts in a fan tray. Do not attempt 
to fix it. Consult your purchase records so that you can determine if the incident 
occurred during the warranty period, and return the faulty fan tray to your 
supplier or to 3Com. The warranty terms are printed in the Switch 4005 Key 
Information Guide
.
Hot Swap
You can remove or install a fan tray while the Switch is powered on. This activity is 
called hot swap