3com 8807 Guida Di Riferimento
RMON Configuration Commands
921
.201326601)*8*100/.1.3.6.1.2.1.2.2.1.5.201326601
Description : ifUtilization.Ethernet5/1/1
Sampling interval : 10(sec)
Rising threshold : 50(linked with event 1)
Falling threshold : 5(linked with event 1)
When startup enables : risingOrFallingAlarm
This entry will exist : forever.
Latest value : 0
display rmon statistics
Syntax
display rmon statistics [ port-num ]
View
Any view
Parameter
port-num: Ethernet port number.
Description
Use the display rmon statistics command to view RMON statistics.
The displayed information includes collision, CRC (Cyclic Redundancy Check) and
queue, undersized or oversized packet, timeout, fragment, broadcast, multicast,
unicast, and bandwidth utility.
queue, undersized or oversized packet, timeout, fragment, broadcast, multicast,
unicast, and bandwidth utility.
Related command: rmon statistics.
Example
# Show RMON statistics.
Table 133 Description on the fields of the display rmon prialarm command
Field
Description
Prialarm table 1
Index of extended alarm entry.
owned by monitor
Creator of the extended alarm entry.
UNDERCREATION
Status of expansion alarms
Samples type
Type of sampling
Variable formula
Formula for expansion alarms
Description
Description information
Sampling interval : 10(sec)
Sampling interval
Rising threshold
Rising threshold. When sampling value rises from normal
value to this threshold, rising threshold alarm will be
triggered.
value to this threshold, rising threshold alarm will be
triggered.
Falling threshold
Falling threshold. When sampling value decreases from
normal value to this threshold, falling threshold alarm will be
triggered.
normal value to this threshold, falling threshold alarm will be
triggered.
linked with event 1
Corresponding event index of ring and falling threshold
alarm.
alarm.
When startup enables:
risingOrFallingAlarm
risingOrFallingAlarm
Kind of first alarm. It may trigger rising threshold alarm or
falling threshold alarm or both.
falling threshold alarm or both.
This entry will exist forever
The lifespan of this alarm entry which can be forever or a
specified period of time.
specified period of time.
Latest value : 0
The value of the latest sampling.