3com 2928 Guida Utente
![3com](https://files.manualsbrain.com/attachments/960452ff43b9899cbcffced60c87abf956e7967a/common/fit/150/50/f6ac125d7af2cf40fec58935fa6d4bf71457a57efe50bee91208a434f325/brand_logo.jpeg)
1-7
Configuring an Event Entry
Select Device > RMON from the navigation tree and click the Event tab to enter the page, as shown in
. Click Add to enter the page for adding an event entry, as shown in
.
Figure 1-5
Event entry
Figure 1-6
Add an event entry
describes the items for configuring an event entry.
Table 1-7
Event entry configuration items
Item
Description
Description
Set the description for the event.
Owner
Set the owner of the entry.
Event Type
Set the actions that the system will take when the event is triggered:
z
Log: The system will log the event
z
Trap: The system will send a trap in the community name of null.
If both Log and Trap are selected, the system will log the event and send a
trap; If none of them is selected, the system will take no action
Configuring an Alarm Entry
Select Device > RMON from the navigation tree and click the Alarm tab to enter the page, as shown in
. Click Add to enter the page for adding an alarm entry, as shown in
.