You must determine the RF level needed by the equipment receiving the RF signal from each 
RF OUT port based on that equipment manufacturer’s recommendations.
We recommend using a spectrum analyzer to measure the RF OUT port’s level.  Connect the 
spectrum analyzer to the RF OUT port; note the spectrum analyzer may require 50-75 Ohm 
matching and the loss from that matching device must be added to the spectrum analyzer read-
ing.
The PFR, with the RF ADJUST control set to fully clockwise position, will output approximately 
45 dBmV.  To reduce the output to the desired level, rotate RF ADJUST for the RF OUT port 
with the spectrum analyzer to the desired level. 
Repeat this process for each RF OUT port that you will be using.
6.  Maintenance
The PFR receiver contains no internal user adjustments or maintenance points.  
6.1  Decreased Performance Due to Contamination
The most likely cause of decreased RF signal quality is contamination in the OPTICAL IN con-
nector.  The optical jumper connectors may be contaminated by the slightest touch to human 
skin or other apparently clean surfaces.  This contamination is transferred in to the PFR bulk-
head connector and remains when the jumper is removed from the PFR receiver.  Over time, it 
will cause decreased and intermittent input levels.  Users may correct this condition as follows 
using commonly available fiber cleaner kits.  One possible source is Fiber Instrument Sales, 
www.fiberinstrumentsales.com.
1.  Remove fiber jumper from OPTICAL IN connector.
2.  Unplug unit from power source. Open top cover by removing 12 screws, sliding top plate back 
and lift at rear.  Find and remove internal fiber connector at OPTICAL IN bulkhead connector 
and set aside.  Exercise care that you do not bend or damage the internal fiber.
3.  Clean bulkhead connector using standard fiber cleaning tools such as Optipop 2.5mm stick 
cleaner.  Slide stick into the bulkhead and scrub contamination of the bulkhead.  If commercial 
tools are not available, a pipe cleaner with isopropyl alcohol may be used. A less effective so-
lution is to use canned (clean) air with nozzle to blow contamination out of the bulkhead. Do 
not use cotton swabs which leave cotton debris.
4.  Clean the internal fiber connector using handheld fiber connector cleaner (as shown earlier in 
this manual) and insert directly into the bulkhead connector until fully seated. If using FC type, 
screw ferrule onto bulkhead connector until snug.   
5.  Clean and insert protective cover in inside of bulkhead connector if an external fiber connector 
is not to be plugged into the PFR immediately.
6.  Replace PFR top cover and snug 12 screws.  Do not overtighten.  Replace in rack and connect 
power cord.
7.  Clean external fiber (jumper) connector using handheld fiber connector cleaner (as shown ear-
lier in this manual) and insert directly into the bulkhead connector until fully seated. If using 
FC type, screw ferrule onto bulkhead connector until snug.