Xerox 242 Manuale Supplementare

Pagina di 262
130
Chapter 6 – Color Workflow
If you selected 
Automatic as the Screening Method in Step 1 of the wizard, you 
need to calibrate the Spire CX260 using two charts. Step 2 of the Calibration 
Wizard appears as follows:
11. Press and hold the button on the side, and align the head with the cyan arrow’s 
tip. The arrow is to the left of the cyan column on the Image Density Calibration 
chart. Its tip intersects the semi-dotted line.
12. Sweep the Eye-One spectrophotometer across the cyan column.
A check mark appears over the cyan icon and instructions appear for the next 
sweep, this time for the magenta column.
13. After each color sweep, wait for the check mark to appear next to the 
appropriate icon and follow the instructions as listed.
When all of the separation columns have been successfully scanned, a check 
mark appears next to all icons.
Note:  Ensure that the separation columns on the chart
 are scanned in the 
order they appear in the icons: 
Cyan > Magenta > Yellow > Black.
Notes:
If at any stage the scanning has not been completed properly, click 
Reset
 and scan again.
If an error occurs while you are scanning the chart, an alert message 
appears. Click 
OK
 and re-scan the charts.
If you selected 
Automatic
 as the 
Screening Method
 in Step 1 of the 
wizard, repeat steps 11-13 for the Text/Line Art chart.