CALIBRATION (con’t)
PITCH WHEEL:
This calibration option allows you to select Pitch Wheel calibration.  
This is a manual calibration that should only be performed if you are 
experiencing trouble with the pitch wheel and believe it needs re-
calibration. Press ENTER to access the Pitch Wheel calibration menu.
You will be asked if you wish to proceed.  Use the VALUE knob to se-
lect YES or NO.  If you are uncertain, or if you change your mind about 
performing this calibration, select NO and press ENTER.  You will be 
returned to the System Utilities Calibration menu.  Otherwise, select 
YES and press ENTER. 
When Pitch Wheel calibration is enabled, the display appears as shown. 
The values displayed indicate the minimum, middle and maximum posi-
tions of the pitch wheel.
When you see this display, perform the following operations:
1.)  Move the Pitch Wheel to the minimum position (all the way to-
wards you).  The left-hand number will go to some minimum value.
2.)  Move the Pitch Wheel to the maximum position (all the way 
towards the panel).  The right-hand number will go to some maximum 
value.
3.)  Release the Pitch Wheel and let it snap back to the middle position.  
The middle number should settle around 2048 (±20).
This completes the Pitch Wheel calibration. To exit the calibration, press 
ENTER to return to the System Utilities Calibration menu or press 
MASTER to exit the calibration and return to the highest level of the 
System Utilities menu.
Note:  If this calibration is done incorrectly, the Pitch Wheel will not operate normally and may 
not function at all. If this should this happen, try recalibrating the Pitch Wheel again using the 
procedure described.