SERVICE (cont.)
TANK HEATER (Cont.)
TANK HEATER SWITCH
Location:
The tank heater switch is located on the rear
of the brewer on the upper left side of the trunk.
Test Procedure:
1.
Disconnect the brewer from the power source.
2.
Disconnect the black wire from the limit thermo-
stat.
3.
With the tank heater switch in the "ON" position
check the voltage between the black wire re-
moved from the limit thermostat and the white
wire or red wire on the tank heater with a voltme-
ter. Connect the brewer to the power source. The
indication must be:
a) 120V volts ac on two wire 120 volt models.
b) 240 volts ac on three wire 120/240 volt mod-
els.
c) 200 to 230 volts ac on 200 volt or 230 volt
models.
4.
Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the
Wiring Diagrams  and check the brewer wiring har-
ness.
P1153
10841 020503
P1168
WHI to Terminal Block
(White Insert on 120V
Two Wire Models)
RED to Terminal Block
(Red Insert on 120/240V
Threee wire Models or
200V and 230V Two
Wire Models)
BLK to Control
Thermostat (Brewers
W/Out Faucet) Thermal
Cut-Off to BLK from
Control Thermostat
(Brewers W/Faucet
15. Reconnect the wires to the limit thermostat, tank
heater and control thermostat. See limit thermo-
stat and control thermostat sections in this manual
when reconnecting wires.
16. Install fill basin, secure with tank inlet fitting and
gasket. Insert water supply line through grom-
met in fill basin.
17. Refer to the illustration below when reconnecting
the tank heater wires.