Avaya a500 Guida Utente
admin Commands
Cajun A500 ATM Switch User Guide
6-47
admin time
Purpose
The
admin time
command sets the Cajun A500s internal clock.
Syntax
admin time { dd mm yy hh mm }
Arguments
This command requires the following argument(s). All parameters are numerical
representations.
Example
A500:admin time 12 05 98 17 02
The current system date is Tuesday, May 12, 1998 5:02:00p
The current system date is Tuesday, May 12, 1998 5:02:00p
dd
Enter the day. For example, 11 for the 11th day of the month.
mm
Enter the month. For example, 01 for January.
yy
Enter the year. For example, 99 for the year 1999. The years 98 and 99
mean 1998 and 1999. All other years entered represent years in the
next century.
hh
Enter the appropriate hour. For example, 10 for 10 a.m. Use 24 hour
time.
mm
Enter the minutes. For example, 22 for 22 minutes.