Solving Problems
ADF Copying Problems (CX11NF Only)
Copies are blank, 
or images are 
missing or faded 
• The sealing tape may still be in the toner cartridge. Remove the 
toner cartridge, pull out the sealing tape, and reinstall the toner 
cartridge as described on page 82.
• If the toner cartridge is low on toner, the copies will be faded. 
Replace the toner cartridge with a new one. 
• The accuracy of the copy depends on the quality and size of the 
original. Try adjusting the Contrast. If your original is too light, the 
CX11N might not be able to compensate, even if you adjust the 
contrast.
• If the original has a colored background, images in the 
foreground may blend too much or the background may be in a 
different shade. 
Completely blank 
pages are output 
• You may have loaded the original upside down. In the Auto 
Document Feeder, load the original with the short edge facing in 
and the side to be scanned facing up. On the document table 
place the original face-down with the top left corner of the 
document located in the lower right corner of the glass.
• The paper may be too damp or rough. Load new paper of another 
type. 
• The toner might be out.
Problem 
Solution
A blank copy is 
output 
• Make sure the ADF and the ADF cover are closed firmly.
• Make sure the paper is loaded correctly.
Problem 
Solution
Basic.book  Page 110  Monday, August 22, 2005  12:35 PM