Processor and Amplifier Settings
Today’s electronic processors and AV receivers have built-in crossover points for small
and large loudspeaker settings. We recommend using the large setting with the R-800
left and right loudspeakers as this loudspeaker is a full range design. At this setting the
R-800 along with two R-88Subs is capable of delivering very high output in practically
any  residential  room.  When  using  more  than  two  subwoofers  and  when  maximum
possible SPL is required or when the room is very large, you can set R800s as small.
This  will  relieve  the  R-800’s  woofers  and  allow  higher  undistorted  output  providing
there  is  sufficient  subwoofer  support  in  the  system.  We  recommend  setting  the  small
setting for R-400C center channel loudspeaker for optimum performance.
Before  using  your  processor’s  auto-level  set  up  routine  (level  calibration)  and
automatic room EQ (where this option is available) we recommend performing a level-
balancing procedure for the R-800 and R-88Sub controls. Setting the BGA-2500 Level
knob  at  the  1  o’clock  setting  will  provide  balanced  frequency  response  for  the  R-800
loudspeaker at 10-ft. (3 meters). In most cases your setting should not vary too much
from  this  recommended  level.  However,  different  receivers  and  amplifiers  that  will
power the R-800 ribbon planar array usually have different amplification factor or gain
and room acoustic parameters will affect the sound as well. Therefore it is important to
set  BGA-2500  controls  properly  to  make  sure  that  the  R-800’s  woofers  deliver  the
same  output  as  the  planar  ribbon  array  at  the  listening  position  and  overall  sound  is
spectrally  balanced.  Connect  all  speakers  and  electronics  in  the  system  as  indicated
on either of the above diagrams. Set BGA-2500 controls as recommended below.
R-800:
1.  Set BGA-2500 Phase control knob at 0° (Note: When used together with the R-800,
the phase knob on the BGA-2500 amplifier should always be set at 0°).
2. Set Crossover switch at 250Hz.
3. Set Level potentiometer knob at about the 1 o’clock position.
4.  Sit  in  the  primary  listening  location,  preferably  at  equal  distance  between  two
loudspeakers and not closer than 10 feet (3 m) to the screen. Turn on your test or
favorite stereo recording (preferably with vocal content) and listen to it through one
speaker  (left  or  right).  Keep  adjusting  Level  knob  to  the  point  when  the  sound  is
optimally balanced. To confirm the results, listen to several different recordings and
through both loudspeakers in stereo.