Classification:
"Lithium Coin"
Chemical System:
Lithium / Manganese Dioxide (Li/MnO
2
)
Designation:
ANSI-5012LC, IEC-CR1220
Nominal Voltage:
3.0 Volts
Typical Capacity:
40 mAh (to 2.0 volts)
(Rated at 45K ohms at 21°C)
Typical Weight:
0.78 grams (0.03 oz.)
Typical Volume:
0.25 cubic centimeters (0.02 cubic inch)
Max Rev Charge:
1 microampere
Energy Density:
153 milliwatt hr/g, 464 milliwatt hr/cc
Typical Li Content:
0.006 grams (0.0002 oz.)
UL Listed:
MH12454
Shipping: 
For complete details, please reference:
Special Provision A45 of the International
Air Transport Association Dangerous
Goods Regulations
49 CFR 173.185
Load
Cutoff
2.0V
(ohms)
(hours)
45,000
628
Bkgnd Drain: Continuous
62K ohms
0.046 mA @2.85V
Pulse Drain: 2 seconds X 12 times/day
1K ohms
2.8 mA @2.65V
Simulated Application test
Typical Performance at 21°C (70°F)
Continuous
Specifications
mm (inches)
Industry Standard Dimensions
United States:
Global (except US):
Safety :
1) KEEP OUT OF REACH OF CHILDREN.  Swallowing may lead to 
serious injury or death in as little as 2 hours due to chemical burns and 
potential perforation of the esophagus.  Immediately see doctor; have 
doctor phone (202) 625-3333. 
(2) Battery compartment design. To prevent children from removing 
batteries, battery compartments should be designed with one of the 
following methods: a) a tool such as screwdriver or coin is required to 
open battery compartment or b) the battery compartment door/cover 
requires the application of a minimum of two independent and 
simultaneous movements of the securing mechanism to open by hand. 
Screws should remain captive with the battery door or cover.
Lithium Coin
 ©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Typical Drains:
at 2.85V 
(mA)
0.064
Pulse Test at 21°C (70°F)
Typical Discharge Characteristics
Internal Resistance Characteristics
Important Notice
This datasheet contains typical information specific to products manufactured at the time of its publication. 
ENERGIZER CR1220
Schedule:
PRODUCT DATASHEET
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
0
100
200
300
400
500
600
700
V
o
lt
a
g
e
, CCV
Service, Hours
Load: 45K ohms - Continuous
Typical Drain @ 2.9V: 0.064 mA
40
80
120
160
200
240
280
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
0
5
10 15 20 25 30 35 40 45 50
IR,
 o
h
m
s
V
o
lt
a
g
e
, CCV
Capacity, mAh
IR
Pulse
Bkgnd
1-800-383-7323 USA/CAN
www.energizer.com
2.00 (0.079)
1.80 (0.071)
1.60 (0.063) Ref.
1.40 (0.055) Ref.
12.25 (0.482)
12.50 (0.492)
4.00 (0.157)
Minimum
0.20 (0.008) Maximum Ref.
Permissible deflection from a flat.
0.03 (0.001) Minimum Ref.
(Applies to top edge of gasket or
edge of crimp, whichever is higher.)
This Battery has Underwriters 
Laboratories component Recognition
Form No. EBC - 4113I