Energizer ECR1216BP Scheda Tecnica

Pagina di 1
Classification:
"Lithium Coin"
Chemical System:
Lithium / Manganese Dioxide (Li/MnO
2
)
Designation:
ANSI-5034LC, IEC-CR1216
Nominal Voltage:
3.0 Volts
Typical Capacity:
34 mAh (to 2.0 volts)
(Rated at 62K ohms at 21°C)
Typical Weight:
0.6 grams (0.02 oz.)
Typical Volume:
0.2 cubic centimeters (0.01 cubic inch)
Max Rev Charge:
1 microampere
Energy Density:
118 milliwatt hr/g, 413 milliwatt hr/cc
Typical Li Content:
0.008 grams (0.0003 oz.)
UL Listed:
MH12454
Shipping: 
For complete details, please reference:
Special Provision A45 of the International
Air Transport Association Dangerous
Goods Regulations
49 CFR 173.185
Load
Cutoff
2.0V
(ohms)
(hours)
62,000
739
Bkgnd Drain: Continuous
62K ohms
0.046 mA @2.85V
Pulse Drain: 2 seconds X 12 times/day
1K ohms
2.8 mA @2.8V
 ©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Typical Drains:
at 2.85V 
(mA)
0.046
Pulse Test at 21°C (70°F)
Typical Discharge Characteristics
Internal Resistance Characteristics
Important Notice
This datasheet contains typical information specific to products manufactured at the time of its publication. 
Continuous
Simulated Application test
Lithium Coin
ENERGIZER CR1216
Schedule:
Specifications
mm (inches)
Industry Standard Dimensions
United States:
Global (except US):
Typical Performance at 21°C (70°F)
Safety:
(1) KEEP OUT OF REACH OF CHILDREN.  Swallowing may lead to 
serious injury or death in as little as 2 hours due to chemical burns and 
potential perforation of the esophagus.  Immediately see doctor; have 
doctor phone (202) 625-3333. 
(2) Battery compartment design. To prevent children from removing 
batteries, battery compartments should be designed with one of the 
following methods: a) a tool such as screwdriver or coin is required to 
open battery compartment or b) the battery compartment door/cover 
requires the application of a minimum of two independent and 
simultaneous movements of the securing mechanism to open by hand. 
Screws should remain captive with the battery door or cover.
PRODUCT DATASHEET
1-800-383-7323 / USA
1-800-383-7323 / CANADA
1-800-383-7323 USA/CAN
www.energizer.com
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
0
200
400
600
800
V
o
lt
a
g
e
, CCV
Service, Hours
Load: 62,000 ohms - Continuous
Typical Drain @ 2.85V: 0.046 mA
0
40
80
120
160
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
0
5
10
15
20
25
30
35
IR,
 o
h
m
s
V
o
lt
a
g
e
, CCV
Capacity, mAh
IR
Pulse
Bkgnd
1.60 (0.063)
1.40 (0.055)
1.40 (0.055) Ref.
1.10 (0.043) Ref.
12.20 (0.480)
12.50 (0.492)
4.00 (0.157)
Minimum
0.30 (0.012) Maximum Ref.
Permissible deflection from a flat.
0.03 (0.001) Minimum Ref.
(Applies to top edge of gasket or
edge of crimp, whichever is higher.)
This Battery has Underwriters 
Laboratories component Recognition
Form No. EBC - 4112K
Page 1 of 1