Power rating: 
10, 15, 20 and 30 kVA at  
 
0.9 power factor (three phase)
Form factor: 
Small-footprint tower, black
Topology: 
Double conversion
Battery backup: 
 Up to 22 minutes typical,  
extendable up to three hours
Input voltage: 
208V/120V or 220V/127V
Output voltage: 
208V/120V or 220V/127V
 
480V: 120V/208V or 600V: 
 
 120/208 with input isolation  
transformer (at 60 Hz only)
Frequency: 
50/60 Hz auto-sensing
Dimensions: 
 10 and 15 kVA two-high configuration: 
32.2" H x 12" W x 32.5" D
 
 10 and 15 kVA three-high configuration:  
47.8" H x 12" W x 32.5" D
 
20 and 30 kVA:  66" H x 20" W x 34" D
The Eaton
®
 9355 is a mid-size, three-phase uninterruptible 
power system (UPS) that delivers superior power protection 
for the ever-expanding loads in today’s space-constrained 
data centers. 
The double-conversion topology of the 9355 means that it 
protects IT infrastructure from all of the most common power 
problems to give data center managers greater peace of 
mind. The 9355 also offers an industry-leading combination  
of flexibility, scalability and power density—all in an 
innovative, high-efficiency package. 
The 9355’s sleek, end-of-row tower design is 
available in 10 kVA and 20 kVA configurations, 
upgradeable to 15 kVA and 30 kVA, respectively, 
and offers the smallest footprint of any comparable UPS. 
Standard internal batteries often eliminate the need for costly 
and space-consuming external battery cabinets. 
An on-board power distribution module gives data 
center managers additional flexibility by helping to 
preserve valuable rack space and making the rack-
based environment truly plug and play. This module 
can be configured for hardwired output or with a variety of 
output receptacles, reducing site preparation and installation 
expenses. 
Up to four 9355 UPSs can be paralleled for either 
redundancy or extra capacity using Eaton’s patented 
Powerware
®
 Hot Sync
®
 paralleling technology. 
Powerware Hot Sync also enables wireless paralleling in the 
event of a communications failure, providing the industry’s 
only truly redundant paralleling solution. 
The 9355’s space-efficient design and outstanding 
performance and reliability make it perfect for corporate, 
telecom, healthcare, banking, industrial and retail applications. 
Combined with Eaton’s world-class warranty and service plans, 
expert technical support, and broad selection of options—and 
backed by 40 years of R&D excellence—the 9355 is the ideal 
power protection solution for small data centers.
Agility, scalability and space efficiency –  
with greater standard runtime
Product snapshot