Omnitron iConverter OC12FF 8681-1 Manuale Utente
Codici prodotto
8681-1
speciFications
Management of the plug-in module is accomplished by using
a Management Module (such as an iConverter NMM2 or
10/100M2) that provides monitoring, configuration and trap
notification. The management module can be accessed via
SNMP, Telnet, or serial port. The SNMP-based management
is accomplished via Omnitron’s intuitive, graphic-oriented
NetOutlook management software or third party SNMP
management software, while the Telnet and the serial interfaces
have an easy-to-use, menu-driven interface.
Real-time OC12FF parameters that can be monitored include
Real-time OC12FF parameters that can be monitored include
power, link, data receive status, module type and model,
hardware and software revisions, serial numbers and a user-
defined identifier.
The user can override the OC12FF module’s physical
The user can override the OC12FF module’s physical
DIP-switch settings by using SNMP or Telnet to configure
DIP-switch-selectable parameters such as Link Propagate or
Remote Fault Detection.
In addition to all standard iConverter SNMP traps such as
In addition to all standard iConverter SNMP traps such as
module insertion and removal, the OC12FF modules can
generate traps on port state changes including link-up and
link-down. Trap monitoring of specific events can be selectively
enabled or disabled by the network administrator.
Page 2
ManageMent
iConverter
OC12FF
Model Type
iConverter
OC12FF
Protocols
OC-12, STM-4
Compliance
UL, FCC Class A, CE, NEBS Level 3
Fiber Connectors
SC, Single-Fiber SC
Controls
LP, RFD
LED Displays
Power, FO link (2)
Dimensions
Plug-in:
Standalone:
Standalone:
W 0.85” x D 4.5” x H 2.8”
W 3.8” x D 4.8” x H 1.0”
W 3.8” x D 4.8” x H 1.0”
Weight
Plug-in:
Standalone
Standalone
without Power Adapter:
Standalone
Standalone
with Power Adapter:
8 oz.
1.0 lb.
1.5 lb.
DC Power Connector
Plug-in:
Standalone:
Standalone:
Power supplied by backplane
2.5mm Barrel Connector or
2.5mm Barrel Connector or
2 Pin Terminal Connector
DC Power
Requirement (typical)
Plug-in:
Standalone:
Standalone:
0.5A @ 3.3VDC
5 - 32VDC
5 - 32VDC
0.3A @ 9VDC (1.0A max)
AC Power Adapter
[US]
Plug-in:
Standalone:
Standalone:
N/A
100 - 120VAC/60Hz
100 - 120VAC/60Hz
0.05A @ 120VAC
AC Power Adapter
[Universal]
Plug-in:
Standalone:
Standalone:
N/A
100 - 240VAC/50 to 60Hz
100 - 240VAC/50 to 60Hz
0.05A @ 120VAC
Temperature
Standard:
0° to 50° C
Wide:
- 40° to 60° C
Storage:
- 40° to 80° C
Humidity
5 to 95% (non-condensing)
Altitude
- 100m to 4000m
MTBF (hrs)
Plug-in:
1,600,000
Standalone
with US Power Adapter:
250,000
Standalone
with Universal Adapter:
100,000