❚❚Measuring a Value for White Balance
1
Light a reference object.
Place a neutral gray or white object under the lighting that will 
be used in the final photograph. In studio settings, a standard 
gray panel can be used as a reference object. Note that 
exposure is automatically increased by 1 EV when measuring 
white balance; in exposure mode h, adjust exposure so that 
the electronic analog exposure displays shows ±0 (pg. 122).
2
Set white balance to 
L ([Preset manual]).
Press the WB button and rotate the main command dial until 
L is displayed in the rear control panel.
WB
 button
Main command dial
Rear control panel