Canon VB-R13VE Manuale

Pagina di 173
S
ystem Management
 With RM Ma
nager
4
57
[Tools] menu
[Recording Schedules]
Displays the [Recording Schedules] window. You can configure recording schedules (P. 72).
[Tags]
Displays the [Tag Settings] dialog box. You can add, change names, and delete tags here.
[Backup/Restore Configuration]
Backs up or restores settings data for Storage Servers, registered cameras, recording schedules, etc. By backing up 
settings before editing them, you can restore to a previous state even after changing the settings.
To back up settings, select the backup destination folder in the [Backup] tab, and click [Start Backup]. A folder with 
a name that starts with “NVR30” will be created in the specified folder, and the backup files and folders will be stored 
in the folder.
To restore settings, select the folder with the name that starts with “NVR30” that was created during backup in the 
[Restore] tab, and click [Start Restore].
[Change IP Address]
Changes the IP address set in the Storage Server. If the IP address of the Storage Server computer changes, the IP 
address settings must also be updated (P. 163).
[Change License]
If, for example, you upgrade from RM-9 to RM-25 or from RM-25 to RM-64, you can change the license when a new 
one has been obtained (P. 165).
[Reset Servers Reference Time]
Synchronizes the Storage Server service time and the Storage Server computer time. Because this is adjusted 
periodically under normal circumstances, there is no need to use this option. Please only use this option if the 
Storage Server computer time is significantly affected, such as when changing time zones.
Important
• Recorded video, event data, and server log data will not be backed up. For details on preparing for system or equipment 
failures, please refer to “Chapter 8 Backup” (P. 139).
• Restoring backed up settings data returns the state of camera registration and various settings to that at the time of backup. Be 
aware that recorded video and events for cameras added after the backup procedure will not be viewable. We recommend 
performing backup again after registering new cameras.