ASUS RS700-E7/RS4 Manuale Utente

Pagina di 196
Chapter 2:  Hardware setup
2-24
2.8.3 
Replacing optical drive (optional)
This server system supports a slim-type optical disk drive. Follow the steps below 
to replace the optical disk drive. 
1.  Remove the screw that secures the 
optical drive. Keep the screw for 
reassembly.
2.  Remove the SATAII/SAS drive tray 
by pushing the spring lock to the 
right, then pulling the tray lever 
outward. The drive tray ejects 
slightly after you pull out the lever.
3.  Firmly hold the tray lever and pull 
the drive tray out of the bay.
4.  Pull the optical drive module.
5.   Carefully insert the replacement 
optical disk drive module into the 
drive bay until it is securely seated 
in place.
6.  Carefully insert the drive tray and 
push it all the way to the depth of 
the bay until just a small fraction of 
the tray edge protrudes.
7.  Push the tray lever until it clicks, 
and secures the drive tray in place. 
The drive tray is correctly placed 
when its front edge aligns with the 
bay edge.
8.  Secure the optical drive with the 
screw that you removed in step 1.