KitchenAid 48" Designer Commercial-Style Hood Utilizzo E Cura

Pagina di 28
7
Range Hood Mounting Screws Installation
1. Determine and mark the centerline on the wall where the 
range hood will be installed.
2. Based on the ceiling or soffit height, determine the distance 
“X” (30" [76.2 cm] min., suggested 36" [91.4 cm] max.) 
needed between the cooking surface and the bottom of the 
range hood. To this distance, add 19" (48.3 cm) and draw a 
horizontal line (A) about 24" (61.0 cm) long centered on the 
vertical centerline (B) at this distance.
3. Following the illustrations in Step 4, mark points on each side 
of the horizontal line as measured from the vertical centerline.
4. Drill 
³⁄₃₂" (2.4 mm) pilot holes for installation into wood. The 
screws provided for mounting this range hood must be 
fastened into solid wood. Do not fasten only into sheet rock.
For 36" (91.4 cm) models - 2 mounting holes
For 48" (121.9 cm) model) - 4 mounting holes
5. Install the #10 Phillips head mounting screws. Leave a 
¹⁄₄" (6.4 mm) gap between the wall and the back of the screw 
head to slide range hood into place.
Chimney Support Bracket Installation
1. Place two of the chimney brackets against the wall so that 
their top edges are 
¹⁄₁₆" (2.0 mm) from the ceiling or soffit and 
level. Mark holes.
2. Place the other two chimney brackets on the wall so that their 
lower edges are 16
¹⁄₁₆" (40.8 cm) from the ceiling or soffit and 
level. Mark holes.
3. Drill pilot holes.
If installing into wood, drill 4 - 
³⁄₃₂" (2.4 mm) pilot holes.
4. Attach each bracket to the wall with a #10 Phillips head 
mounting screw. Tighten screws securely.
Complete Preparation
1. Determine and make all necessary cuts in the wall for the vent 
system. Install the vent system before installing the range 
hood. See the “Venting Requirements” section.
2. Determine the location where the power supply cable will be 
run through the wall. Be sure that the location will be covered 
by the chimney of the range hood.
3. Drill a 1
¹⁄₄" (3.2 cm) hole at this location.
4. Pull enough power supply cable through the wall to allow for 
easy connection to the terminal box.
5. If roof or wall cap does not have a damper, attach damper to 
exhaust openings on top of the range hood using 2 Phillips 
head screws.
6. If the 48" (121.9 cm) range hood is to be connected to the 
10" (25.4 cm) round vent system, install the vent transition 
piece now.
A. Horizontal line
B. Vertical centerline
C. Cooking surface
D. Distance “X” (30" [76.2 cm] min., suggested 
36" [91.4 cm] max.) + 19" (48.3 cm)
A. Horizontal line
B. Vertical centerline of range hood
C. 4
⁹⁄₁₆
" (11.6 cm)
A. Horizontal line
B. Vertical centerline of range hood
C. 1
⁵⁄₁₆
" (3.3 cm)
D. 9
¹⁄₈
" (23.2 cm)
A
B
C
D
X + 19" (48.3 cm)
A
B
C
A
B
C
D
D
C
A. Vertical centerline
B.
¹⁄₁₆
" (1.6 mm)
C. 11" (27.9 cm)
¹⁄₄
"
(6.4 mm)
B
A
C
C
16
¹⁄₁₆
"
(40.8 mm)