KitchenAid 36" Wall-Mount Canopy Hood Guida All'Installazione
8
5. Remove terminal box cover.
6. Remove the knockout in the range hood back cover and
install a UL listed or CSA approved ½" strain relief with the
strain relief clamping screws on the inside of the terminal box.
strain relief clamping screws on the inside of the terminal box.
Install Range Hood
Vented Installations
1. Install damper on top of the exhaust opening. Check that the
damper opens freely.
2. Go to “Mount the Range Hood” in this section.
Non-vented (recirculating) Installations
NOTE: Recirculating Kit Part Number W10272172 is required.
See the “Assistance or Service” section to order.
See the “Assistance or Service” section to order.
1. Install the non-vented (recirculating) diverter supplied with the
recirculating kit.
2. Fit the diverter over the vent motor exhaust outlet and push
down to seat on outlet. Check that the diverter exhaust
outlets are parallel with the vent motor sides so that they will
align with the vent cover openings in the lower chimney.
outlets are parallel with the vent motor sides so that they will
align with the vent cover openings in the lower chimney.
3. Install the charcoal filters included with the recirculating kit.
See the “Range Hood Care” section.
Mount the Range Hood
1. Using 2 or more people, lift the range hood and place the
mounting hood brackets over the mounting screws.
2. Run the home power supply cable (black, white and green
wires) through the strain relief in the back of the range hood
and into the terminal box.
and into the terminal box.
3. Push the range hood into its mounted position. The ½" strain
relief should fit into the 1¼" diameter hole when the range
hood is seated into position.
hood is seated into position.
4. Securely tighten the mounting screws.
Make Electrical Connection
1. Disconnect power.
2. Use UL listed wire connectors and connect black wires (B)
together.
3. Use UL listed wire connectors and connect white wires (D)
together.
A. Diverter
B. Vent canopy
B. Vent canopy
A
B
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
range hood.
Failure to do so can result in back or other injury.
A. Home power supply cable
B. Black wires
B. Black wires
C. UL listed wire connectors
D. White wires
D. White wires
E. Green (or bare) ground wire from home
power supply connected to green ground
screw
screw
F. Range hood power supply cable
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
B
C
D
E
F