Xerox DocuTech 180 HighLight Color System Guida Utente

Pagina di 180
3-24
DocuTech 128/155/180 HighLight Color Operator Guide
Routine maintenance
6. Then, turn the yellow CCU handle a quarter turn clockwise.
Figure 3-20  Removing the CCU from the printer
11. Using the metal flange of the color CCU, pull the CCU out of 
the printer until it is completely in the stand. The flange is 
located directly below the bottle.
12. To replace the CCU, reverse the above steps.
Adding fuser shield
When directed by a message, add fuser lubricant as soon as 
possible. If it is not added, the printer stops after approximately 
5,000 prints and not run until fuser shield is added. Please read 
the important note below.
NOTE:  In 2006, the formula for the DocuTech HLC fuser lubricant 
was changed to provide better image quality and to prevent image 
transfer. The new fuser formula is called Fuser Shield. The fuser 
blend and the fuser shield CANNOT be intermixed in a DocuTech 
HLC. To change from one fuser lubricant to another requires a 
service call and cleaning or replacing components. The two fuser 
formulas are identified with different color bottles and caps. Be 
sure the color of the cap of the bottle you are filing from matches 
the color of the cap already in the system. Fuser shield 
description: blue bottle, white cap with black printing. Fuser blend 
description: yellow bottle, black cap with white printing.
WARNING:  The fuser area can reach temperatures of 
approximately 425°F (218°C). Exercise care to prevent burns 
when working in this area.