Cleaning the Fuser Assembly
If you see dry ink / toner debris on the back of the printout, select and run the Clean
Fuser Assembly 
routine from the press UI to automatically clean the fuser component.
This process addresses image quality issues caused by contaminants in the fuser.
Note
If you still notice contaminants on the back of the prints after running this procedure,
contact Xerox Service. Dry ink / toner debris can originate from either one of two areas
in the press: the Transfer Roll or the Fuser Assembly Roll.
Important
While this cleaning procedure can be performed by the operator in Guest mode, only
the Administrator mode can select from two methods of cleaning. In Guest mode,
cleaning the fuser is restricted to running blank sheets only.
1. Log in as Administrator.
2. Press the Machine Status button on the UI.
3. Select the Tools tab.
4. Select Setup & Calibration > Clean Fuser Assembly.
This routine can also be accessed by selecting System Settings > Common Service
Settings > Maintenance > Clean Fuser Assembly
5. From the screen that displays, select the method the routine will use to remove the
unfused dry ink / toner:
• Clean with Paper - press prints blank sheets to remove the dry ink / toner from
the fuser
• Clean with Felt - press removes the dry ink / toner from the fuser by applying the
felt against the pressure roll (no paper is used)
6. If you selected the Clean with Paper option:
a) From Paper Supply, select the paper tray to use.
Note
Any type of paper and size can be used. However, the smooth surface of coated
paper does offer more contact area to the pressure roll.
b) From Number of Sheets, select the number of blank sheets to run (1 to 5).
Note
For best results, run a minimum of 5 sheets.
7. Select Save.
8. Press the Start button. The system begins the cleaning process and displays a
"successfully completed" message when finished. Select OK.
5-19
Xerox
®
Versant
®
80 Press
System Administration Guide
Setup and Calibration (Tools Administrator Mode)