Honeywell Honeywell Security | Protect What Matters Most Guida Utente

Pagina di 72
 
 
– 8 – 
System Overview (cont’d) 
Device Timers 
The system provides up to 20 "timers" that can be used to control various 
devices, such as lights or appliances. These timers are similar in concept to 
the individual appliance timers that might be purchased at a department 
store. The devices that can be controlled are programmed into the system by 
the installer. Up to 96 of these devices can be programmed. Refer to the 
PROGRAMMING DEVICE TIMERS section for procedures. 
To Access Another Partition (GOTO Command) 
Each keypad is assigned a default partition for display purposes, and will 
show only that partition's information. But, if the user is authorized, a 
keypad in one partition can be used to perform system functions in another 
partition, by using the GOTO command. Note that only those partitions 
authorized and programmed by the installer can be accessed in this manner. 
To GOTO another partition, enter your security code, then press [
] followed 
by the desired partition number (1-8). 
The keypad will remain in the new partition until directed to go to another 
partition, or until 120 seconds has elapsed with no keypad activity. Entering 
your security code, pressing [
] followed by [0] will return the keypad to its 
original partition. 
Master Keypad Operation 
A "Master" keypad is one on which the status of all 8 partitions is displayed 
simultaneously.  A user can get more information about a certain partition by 
simply entering [
] + the desired partition number (1-8).  To log on to the 
"Master" partition (9) using the GOTO command, and to perform any 
functions at a Master keypad, a user must have access to all partitions.