ELECTRICAL CONNECTION 
•  Connect the hood to the mains through a two-pole 
switch having a contact gap of at least 3 mm. 
• Remove the grease filters (see paragraph Mainte-
nance) being sure that the connector of the feeding 
cable is correctly inserted in the socket placed on the 
side of the fan. 
 
Flue assembly 
Upper exhaust flue 
•  Slightly widen the two sides of the upper flue and 
hook them behind the brackets 7.2.1, making sure 
that they are well seated. 
•  Secure the sides to the brackets using the 4 screws 
12c (2,9 x 9,5) supplied. 
Lower exhaust flue 
•  Slightly widen the two sides of the flue and hook 
them between the upper flue and the wall, making 
sure that they are well seated. 
•  Fix the lower part laterally to the hood body using 
the 2 screws 12c (2,9 x 9,5) supplied. 
•  Make sure that the air outlet connection is aligned 
with the chimney outlets. 
 
12c
12c
12c
2.2
2.1
2