Philips GC 6602/20 SpeedCare белый/голубой Manuale Utente

Pagina di 92
Safety auto-off mode (specific types only)
 - To save energy, the steam generator switches off automatically when it has not been used for  
15 minutes. The ‘iron ready’ light flashes.
 - To reactivate the steam generator, set the on/off switch to ‘off’ position and then to ‘on’ position.
Troubleshooting
This chapter summarises the most common problems you could encounter with the appliance. If you 
are unable to solve the problem with the information below, visit www.philips.com/support  
for a list of frequently asked questions or contact the Consumer Care Centre in your country. 
Problem
Possible cause
Solution
The iron does 
not produce any 
steam.
There is not enough water in 
the water tank.
Fill the water tank beyond the MIN 
indication. Press and hold the steam trigger 
until steam comes out. It may take up to 
30 seconds until steam comes out.
You have not pressed the steam 
trigger.
Press and hold the steam trigger until 
steam comes out.
You have set the temperature 
dial to 1.
Turn the temperature dial to 2 or higher.
The steam function has been 
disabled until you have 
performed the Calc-Clean 
process.
Perform the Calc-Clean process to restore 
the steam function (see chapter 
‘IMPORTANT - Cleaning and 
maintenance’).
The Calc-Clean 
light flashes and 
the appliance 
beeps.
This is the Calc-Clean reminder. Perform the Calc-Clean process within  
1 hour after the Calc-Clean reminder  
is given.
The Calc-Clean 
light flashes and/
or the appliance 
beeps.
You have not done or have not 
completed the Calc-Clean 
process.
Perform the Calc-Clean process to enable 
the steam function again (see chapter 
‘IMPORTANT - Cleaning and 
maintenance’).
The Calc-Clean 
light flashes and 
the appliance 
beeps every time 
I press the steam 
trigger. No steam 
comes out of the 
soleplate.
You have not done or have not 
completed the Calc-Clean 
process.
Perform the Calc-Clean process to enable 
the steam function again (see chapter 
‘IMPORTANT - Cleaning and 
maintenance’).
The appliance has 
switched off.
The safety auto-off function was 
activated. This  happens 
automatically when the steam 
generator has not been used or 
the steam trigger has not been 
pressed for more than 15 
minutes.
Set the on/off switch to ‘off’ position and 
then to ‘on’ position.
ENGLISH
8