Cisco Cisco ONS 15454 SDH Multiservice Provisioning Platform (MSPP)
6
Release Notes for Cisco ONS 15454 SDH Release 8.5.1
OL-15592-01
Caveats
CSCsj62382
The switchover time is greater than 50ms when LOS-P or SIGLOSS conditions occurs on the trunk port
of 10GE_XP cards with Y-cable setup. This issue will be resolved in a future release.
of 10GE_XP cards with Y-cable setup. This issue will be resolved in a future release.
Electrical I/O Cards
This section documents Electrical I/O Cards caveats in Release 8.5.1.
CSCeg80233
Long traffic hits can occur on E1-42 when using cross-connect FIT cards. This can occur when, on the
FIT card, you toggle the 155 mhz clock going to the E1-42 cards to the off position. This issue cannot
be resolved.
FIT card, you toggle the 155 mhz clock going to the E1-42 cards to the off position. This issue cannot
be resolved.
CSCeg81428
Rarely, a long traffic hit (117 ms) can occur on E1-42 after an XC side switch. In multinode BLSR
setups, switching the cross-connect cards repeatedly might cause traffic hits greater that 60 ms. To avoid
this issue, side switch the XC only when needed (and not repeatedly). This issue will not be resolved.
setups, switching the cross-connect cards repeatedly might cause traffic hits greater that 60 ms. To avoid
this issue, side switch the XC only when needed (and not repeatedly). This issue will not be resolved.
CSCeg19255
Rarely, DS3I VC3 traffic takes a hit greater than 60 ms during a cross-connect card soft reset. This issue
will not be resolved.
will not be resolved.
Hardware
This section documents Hardware caveats in Release 8.5.1.
CSCei36415
When retrieving Gigabit Interface Converter (GBIC) inventory for the FC_MR-4, nothing is returned for
the CLEI code. In a future release, enhanced inventory information will be available for ONS GBICs.
This will include the CLEI code. This issue will be resolved in a future release.
the CLEI code. In a future release, enhanced inventory information will be available for ONS GBICs.
This will include the CLEI code. This issue will be resolved in a future release.
CSCdu82934
When you auto-route a VT circuit on an ONS 15454 node, a path is computed based on the availability
of STSs on the nodes involved. This selection process, when combined with a lack of VT matrix (or
STS-VT connections) on an auto-route selected node, can result in the VT circuit creation failing with
the message “unable to create connection object at node.” To correct this situation, manually route VT
circuits in cases when auto-routing fails. The error message will indicate which node is at issue.
of STSs on the nodes involved. This selection process, when combined with a lack of VT matrix (or
STS-VT connections) on an auto-route selected node, can result in the VT circuit creation failing with
the message “unable to create connection object at node.” To correct this situation, manually route VT
circuits in cases when auto-routing fails. The error message will indicate which node is at issue.