Application Card Installation   
▀  Chassis Slot Numbering and Assignments 
 
 
▄  ASR 5000 Installation Guide 
86 
   
Recommended Minimum Chassis Configuration 
The recommended minimum chassis configuration for application cards, including redundancy, is as follows: 
Slot Number
 
Card
 
Card State
 
SMC 
Active 
SMC 
Standby 
2 and 4 (see Note 1) 
2, 3 and 4 (see Note 2) 
PSC2 or PSC3  Active 
11 (see Notes 1 and 2) 
PSC2 or PSC3  Standby 
 
Notes: 
1. Minimum requirement for hardware redundancy. 
2. Minimum requirement for hardware + software redundancy, MME service, SGSN service, as well as combined 
services on a single platform. 
Install additional cards in the remaining chassis slots as required. 
If you use the session recovery feature, a minimum of three active packet processing cards and one standby (redundant) 