Replacing the CPU
Testing the floppy drive
Step 1
If not already connected, access the CLI by following the procedures in the
and
Step 2
Login as a technician. The tech$ prompt appears.
Step 3
Turn on terminal logging. For information on logging, see the
.
Step 4
Type
hwconfig
and press Enter.
appears.
Step 5
Verify that the “Diskette drive” entry shows that a floppy is present as in Line 19 in
.
Step 6
Test that the floppy drive is correctly installed. See the
for more information.
Replacing the CPU
The section describes how to replace the CPU card (located on the front of the server) and the CPU
transition module (located in the back of the server).
transition module (located in the back of the server).
Warning
Handling the CPU card can result in static damage. Use an anti-static wrist strap, static-dissipating
work surface, and anti-static bags when handling and storing the card.
work surface, and anti-static bags when handling and storing the card.
Note
Any time the CPU card is replaced, you need new license keys for the MeetingPlace server. If you do
not have these, contact the Cisco TAC before proceeding.
not have these, contact the Cisco TAC before proceeding.
Note
The CPU card always goes into slot 7 in the front of the server. It also has a transition module in the slot
7 in the back of the server. Whenever the CPU card is replaced, this transition module must also be
replaced.
7 in the back of the server. Whenever the CPU card is replaced, this transition module must also be
replaced.
Removing the old CPU card
Step 1
Verify all steps in the
have been completed.
Step 2
Locate the CPU card in slot 7 in the front of the server. See
Step 3
With a screwdriver, loosen the CPU card’s captive screws at the top and bottom of the panel. See