Cisco Cisco Unified MeetingPlace Audio Server Manuale Di Manutenzione
A-67
Cisco MeetingPlace Audio Server 5.2 Customer Engineering Guide (for Cisco MeetingPlace 8112)
OL-
Appendix A CLI Reference
update
4) Local File — prompts the user to enter a local file name. The local file path cannot contain
embedded spaces. Forward slashes (“/”) must be used as path separators.
embedded spaces. Forward slashes (“/”) must be used as path separators.
q) (Quit Update) — exits the “update” command.
Options
The “update” command can be used with the following options:
•
update status — shows a quick status of the upgrade. Indicates how long it has been since the last
write to the log file and gives a general system status. If the status shows as “operating”, then an
upgrade is NOT in progress.
write to the log file and gives a general system status. If the status shows as “operating”, then an
upgrade is NOT in progress.
•
update stop — can be used via HyperTerminal session, via the front panel, or via a modem to stop
an upgrade. To continue with the upgrade, you must run the “revert” command, then the “restart”
command to return the system back to its pre-upgrade state. Then you have to begin the upgrade
again.
an upgrade. To continue with the upgrade, you must run the “revert” command, then the “restart”
command to return the system back to its pre-upgrade state. Then you have to begin the upgrade
again.
•
update trace — allows you to monitor the output of an upgrade over a modem line. The display
should be updated every five minutes; however, before declaring the upgrade is stuck, allow 30
minutes.
should be updated every five minutes; however, before declaring the upgrade is stuck, allow 30
minutes.
Note
Before running the “update” command, run the backup procedure to back up the database.
Restrictions
The “update” command can run if the system is up or down, but the batch file loaded from the disk may
refuse to execute if the system is not down. Normally, you should bring the system down before running
the “update” command.
refuse to execute if the system is not down. Normally, you should bring the system down before running
the “update” command.
SEE ALSO
•
Table A-3
Information Needed for Applying Patch via GWSIM Distribution
Description
Value
Obtain information about
Gateway server
Gateway server
Unit number of the Gateway
Unit _________________
Path to the patch file and
patch file name on the
gateway
patch file name on the
gateway
You need to specify the path plus the file
name. For example:
c:/R5.2/Path/update.tar.gz
name. For example:
c:/R5.2/Path/update.tar.gz
Path/name
_______________________
_______________________
_______________________
_______________________