Cisco Cisco Unified MeetingPlace Audio Server Manuale Di Manutenzione

Pagina di 348
D-4  Scheduling parameters 
Cisco MeetingPlace Audio Server System Manager’s Guide
February 27, 2004
Connected until mtg 
ends
Whether the MeetingPlace system 
disconnects the autoanswer device after 
the last participant leaves the meeting.
• When Meeting Controls Device is No
this parameter disconnects all 
autoanswer devices when the owner 
leaves the meeting.
• When Meeting Controls Device is Yes 
and this parameter is No, MeetingPlace 
disconnects all autoanswer devices as 
soon as the last non-autoanswer device 
leaves the meeting.
• When Meeting Controls Device is Yes 
and this parameter is Yes, the 
MeetingPlace system disconnects all 
autoanswer devices when the meeting 
is scheduled to end.
A meeting ends when the Disconnect 
Empty Port Time (DEPT) or Early Release 
Time (ERT) criteria is met.
Meetings with only autoanswer devices in 
attendance are not extended.
Yes, No
Meeting Recording Settings
FF/RR playback incrmt 
(sec)
Number of seconds that MeetingPlace 
fast forwards or rewinds when users listen 
to meeting recordings over the phone.
Numeric—0 to 3600
Max mtg recdg length 
(min)
Maximum recording time in minutes 
allowed per conference.
Numeric—0 to 1400
Recommend setting the same as 
maximum meeting length 
parameter.
Max mtg message 
length (sec)
Maximum length (in seconds) of a single 
meeting message.
Numeric—15 to 1800
Max voice comment 
(sec)
Maximum length of a voice comment in 
seconds.
Numeric—15 to 1800
Warning at end of 
recdg?
Whether attendees hear a warning telling 
them the meeting recording is about to 
end. When No, callers still hear a two-
minute warning.
Yes, No
# of days to retain
Number of days after a meeting for which 
recordings are stored.
Numeric—0 to 60
Prompt Information
End of mtg warning 
(min)
Number of minutes before the scheduled 
end of a meeting to issue a warning.
Numeric—0 to 15
Field
Description
Choices/recommendations